{"product_id":"renogy-160a-2p-dc-molded-case-circuit-breaker","title":"Renogy 160A 2P DC Molded Case Circuit Breaker","description":"\u003cp\u003eThe Suntree DC Molded Case Circuit Breaker is designed to protect DC electrical installations against overloads and short circuits with both the thermal and magnetic tripping mechanism equipped. Once a fault is detected, the circuit breaker automatically switches off the electrical circuit to prevent damage to wires and avoid the risk of fire.\u003c\/p\u003e\n\u003cp\u003eThe circuit breaker can also be manually opened under the full rated load without any damage when electrical maintenance needs to be performed. Engineered for reversible connection, the circuit breaker is allowed to be wired in either direction and functions under bidirectional current. The markings on the handle help identify the contact position of the circuit breaker at a glance. The special design enables easy installation on both the standard DIN rail and the vertical surface.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cstyle\u003e\u003c!--\ntable {\n  font-family: arial, sans-serif;\n  border-collapse: collapse;\n  width: 75%;\n}\ntd, th {\n  border: 2px solid #5A5A5A;\n  text-align: left;\n  padding: 8px;\n}\ntr:nth-child(even) {\n  background-color: #dddddd;\n}\n--\u003e\u003c\/style\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ctable style=\"margin: auto;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e\u003cb\u003ePRODUCT HIGHLIGHTS\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eReliable And Safe\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEquipped with both the thermal and magnetic tripping mechanism for reliability and safety, along with the certification of CE, RoHS, CB, TUV.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDurable For Use\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eExcellent product quality and strong service life. Material and workmanship warranty for 1.5 years.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSizing Tips\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAdvice of choosing suitable circuit breaker for different situations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConnection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eConnected on positive and negative.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMarked Clearly\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in indicator window helps identify the contact position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eQuick To Install\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eOffers DIN rail installation and panel installation. Remember to install the insulation barriers before operation to ensure safety.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003ci\u003eNote:\u003c\/i\u003e More questions about your off-grid power system? Learn more from \u003ca href=\"https:\/\/www.renogy.com\/support\" target=\"_blank\"\u003eRenogy Learning Center\u003c\/a\u003e!\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow to Choose Suitable Circuit Breaker for Controller\/Inverter\/DC Device:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDetermine the maximum continuous operating current as the wattage divided by the voltage.\u003c\/p\u003e\n\u003cp\u003eCalculate the maximum current, which is 1.25 times the maximum continuous operating current.\u003c\/p\u003e\n\u003cp\u003eSelect the circuit breaker whose rated current is greater than and closest to the maximum current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Size Wire Will it Accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe circuit breaker accepts wire sizes ranging from 4 AWG to 4\/0 AWG.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the Difference Between 1P and 2P Circuit Breaker?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1P circuit breakers connect to the live wire only.\u003c\/p\u003e\n\u003cp\u003e2P circuit breakers connect to both the live wire and the neutral wire, allowing them to cut both at the same time. Typically, 2P circuit breakers can handle greater rated current and working voltage than 1P breakers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the Difference Between Fuse and Circuit Breaker?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit Breaker:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFunctions: Provides overload\/short circuit protection and can actively disconnect the circuit.\u003c\/li\u003e\n\u003cli\u003eBreaking Time: Trips quickly for small currents, instant trip for large currents.\u003c\/li\u003e\n\u003cli\u003eRated Operating Voltage: Typically 250V\/1000V.\u003c\/li\u003e\n\u003cli\u003eReplacement: After disconnecting, only a reset is required, with no need for replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFuse:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFunction: Offers overload\/short circuit protection only.\u003c\/li\u003e\n\u003cli\u003eBreaking Time: Can have a delay even for high currents.\u003c\/li\u003e\n\u003cli\u003eRated Operating Voltage: Typically 72V.\u003c\/li\u003e\n\u003cli\u003eReplacement: Immediate replacement is necessary after breaking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the Circuit Breaker Often Connected In?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCircuit breakers are commonly connected in combiner boxes, breaker boxes, home kits, and similar installations.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eSPECIFICATIONS\u003c\/h3\u003e\n\u003cstyle\u003e\u003c!--\ntable {  font-family: arial, sans-serif;  border-collapse: collapse;  width: 75%;  margin-bottom: 20px;}td, th {  border: 2px solid #5A5A5A;  text-align: left;  padding: 8px;}tr:nth-child(even) {  background-color: #dddddd;}\n--\u003e\u003c\/style\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frame Current\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Short-Circuit Breaking Capacity\u003c\/td\u003e\n\u003ctd\u003e15KA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Short-Circuit Breaking Capacity\u003c\/td\u003e\n\u003ctd\u003e20KA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e12KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Life\u003c\/td\u003e\n\u003ctd\u003e10000 Times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Life\u003c\/td\u003e\n\u003ctd\u003e2000 Times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Mechanism\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDamp Heat Resistance\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cb\u003e\u003cu\u003eMechanical Specifications\u003c\/u\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.9 x 3.5 x 5.3 in (200 x 90 x 135 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.67 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Terminal Torque\u003c\/td\u003e\n\u003ctd\u003e44.3 inch·lbs (5 N·m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e4 AWG-4\/0 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40℉~167℉ (-40℃~75℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40℉~167℉ (-40℃~75℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e≤95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Non-Tripping Current\u003c\/td\u003e\n\u003ctd\u003e168A (≥2h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Tripping Current\u003c\/td\u003e\n\u003ctd\u003e208A (\u0026lt;2h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR CuatrerednItnstantaneous Tripping\u003c\/td\u003e\n\u003ctd\u003e1000A (\u0026lt;0.1s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003e\u003cu\u003eAccessories\u003c\/u\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Screw (2)\u003c\/td\u003e\n\u003ctd\u003eM4 x 55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Barrier\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003e\u003cu\u003eCertifications\u003c\/u\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003ctd\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCB\u003c\/td\u003e\n\u003ctd\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTUV\u003c\/td\u003e\n\u003ctd\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003e\u003cu\u003eWarranty\u003c\/u\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial and workmanship warranty\u003c\/td\u003e\n\u003ctd\u003e1.5 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePRODUCT DOCUMENTATION\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.renogy.com\/content\/files\/Manuals\/Warranty.pdf\" target=\"_blank\"\u003eRenogy Warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Renogy","offers":[{"title":"Default Title","offer_id":46911520375074,"sku":"SUNDCCB160MC2P-US","price":126.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0792\/4013\/4946\/files\/11_6eb856b4-15a8-42da-ac81-cd68b0b0ecb2.jpg?v=1697293413","url":"https:\/\/harmoniliving-6620.myshopify.com\/products\/renogy-160a-2p-dc-molded-case-circuit-breaker","provider":"HarmoniLiving","version":"1.0","type":"link"}