{"product_id":"mrcool-geocool-60k-btu-5-ton-downflow-two-stage-cuni-coil-right-w-heater-gchpd060tgtandr","title":"MRCOOL GeoCool 60,000 BTU, 5 Ton, Downflow Two-Stage CuNi Coil Right w\/Heater | GCHPD060TGTANDR","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eThis product is made to order - delivery is expected within 6-8 weeks of purchase.\u003c\/strong\u003e\u003c\/p\u003eMRCOOL GeoCool 60K BTU, 5 Ton, Downflow Two-Stage CuNi Coil Right w\/Heater\u003ch3\u003eSPECIFICATIONS\u003c\/h3\u003e\u003cstyle\u003etable {  font-family: arial, sans-serif;  border-collapse: collapse;  width: 75%;  margin-bottom: 20px;}td, th {  border: 2px solid #5A5A5A;  text-align: left;  padding: 8px;}tr:nth-child(even) {  background-color: #dddddd;}\u003c\/style\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e62.5\" H x 32\" L x 25.75\" W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGCHPD060TGTANDL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI Number\u003c\/td\u003e\n\u003ctd\u003e204370721\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Flow Direction\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvg Coverage Area\u003c\/td\u003e\n\u003ctd\u003e2,500 - 3,000 Sq Ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003eVariable Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor\u003c\/td\u003e\n\u003ctd\u003eTwo Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Phase\u003c\/td\u003e\n\u003ctd\u003e1-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Pump Efficiency (COP)\u003c\/td\u003e\n\u003ctd\u003e5.29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHWG Connection\u003c\/td\u003e\n\u003ctd\u003e1\/2 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Connection\u003c\/td\u003e\n\u003ctd\u003e1 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e65 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Heating Capacity\u003c\/td\u003e\n\u003ctd\u003e55,001 - 60,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height (in)\u003c\/td\u003e\n\u003ctd\u003e62.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length (in)\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width (in)\u003c\/td\u003e\n\u003ctd\u003e25.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (lbs)\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalifornia Residents\u003c\/td\u003e\n\u003ctd\u003eSee Prop 65 WARNING\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003ePRODUCT DOCUMENTATION\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0099\/2251\/0926\/files\/GCHP_Customer_Brochure.pdf?v=1660975714\" target=\"_blank\"\u003eGCHP Customer Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0099\/2251\/0926\/files\/GCHP_Desuperheater_Manual.pdf?v=1660975714\" target=\"_blank\"\u003eGCHP Desuperheater Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0099\/2251\/0926\/files\/gchp-installation.pdf?v=1660975714\" target=\"_blank\"\u003eGCHP Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0099\/2251\/0926\/files\/gchpv-specifications.pdf?v=1660975714\" target=\"_blank\"\u003eGCHP Specification Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0099\/2251\/0926\/files\/gchp-warranty.pdf?v=1660975714\" target=\"_blank\"\u003eGCHP Warranty Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBTU SELECTION GUIDE\u003c\/h3\u003e\n\u003cp\u003eConsult the table below to confirm the necessary BTUs to cool or heat your desired area.\u003cstrong\u003e\u003cbr\u003e \u003cbr\u003e 9K BTU\u003c\/strong\u003e | 180-375 Sq.Ft. \u003cstrong\u003e\u003cbr\u003e 12K BTU\u003c\/strong\u003e | 376-500 Sq.Ft.\u003cbr\u003e \u003cstrong\u003e18K BTU\u003c\/strong\u003e | 501-750 Sq.Ft.\u003cbr\u003e \u003cstrong\u003e24K BTU\u003c\/strong\u003e | 751 - 1,000 Sq.Ft.\u003cbr\u003e \u003cstrong\u003e36K BTU\u003c\/strong\u003e | 1,000-1,500 Sq.Ft.\u003cbr\u003e \u003cstrong\u003e\u003cbr\u003e \u003c\/strong\u003eFactors such as insulation, ceiling height and the number of appliances in the room may impact performance.\u003c\/p\u003e","brand":"MRCOOL","offers":[{"title":"Default Title","offer_id":47244137431330,"sku":"GCHPD060TGTANDR","price":7053.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0792\/4013\/4946\/files\/5-ton-31-eer-2-stage-geocool-geothermal-heat-pump-downflow-package-unit-ha18843-02.3269_1000x_2cbb84b5-d3cc-4e3c-8ef6-c64e9b3778bc.jpg?v=1701845967","url":"https:\/\/harmoniliving-6620.myshopify.com\/products\/mrcool-geocool-60k-btu-5-ton-downflow-two-stage-cuni-coil-right-w-heater-gchpd060tgtandr","provider":"HarmoniLiving","version":"1.0","type":"link"}